What is class 1 insulation?

30 Dec.,2024

 

Grade I Installation

Providing a Grade I installation is important to delivering a quality, energy-efficient home. A Grade I designation means that the home insulation is properly installed and without any moderate or substantial defects. While Grade I installation should be the norm in the residential building industry, there are instances where it is not. The result of a sub-par installation is a home that doesn&#;t perform to its potential&#;which unfortunately reflects poorly on builders, installers and insulation manufacturers alike.

Link to huamei

What are the RESNET grading criteria?

The Residential Energy Services Network (RESNET) has outlined standards that define an insulation installation grading system for use by HERS raters in evaluating installation quality. When inspecting insulation, HERS raters are primarily looking for any missing insulation (voids), gaps or compression.

Summary of RESNET Grading Criteria:

Grade I &#; Minor Defects

Occasional very small gaps are allowed. Voids can&#;t extend from the interior to the exterior (i.e. the full width of a wall cavity). The product is installed according to manufacturer&#;s specification and cut to fit around electrical junction boxes and is split around wires and pipes. Compression or incomplete fill amounting to 2% or less, if the empty spaces are less than 30% of the intended fill thickness, are acceptable for Grade I.

Grade II &#; Moderate Defects

Can have minor compression and up to 2% missing insulation. Can also have moderate to frequent gaps around wiring, electrical outlets, plumbing and other intrusions. It&#;s important to note that the grading system treats and assesses missing insulation differently than compressed insulation.

See More

&#;

+

Compression/incomplete fill vs. missing insulation

Understanding the different uses of the &#;2% rule&#; and its impact on grading is essential.

  • If 2% or less of the area is compressed or has incomplete fill it can still be considered Grade 1
  • If 2% or less of the area has missing insulation it will be considered Grade 2

Grade III &#; Substantial Defects

Has substantial gaps and voids with missing insulation comprising more than 2% of total area. Installations not complying with the minimum installation requirements and Grade I or Grade II requirements above are a Grade III installation.

To read the full text from the RESNET Manual, click here and refer to Appendix A, pages A-11 through A-16.

Resources to get you a Grade I Installation

On this website we offer detailed instructions, as well as videos and visual guides, including:

Also, the RESNET Manual specifically states that the following NAIMA publications may be used as references for proper installation:

Ready to Start Installing?
View our Tutorials to Begin Download this page as a PDF

Understanding IEC Appliance Insulation Classes: I, II and III

Insulation can be in the form of creepage and clearance distances as opposed to an applied material or coating. Creepage is the distance measured over a surface, such as between two traces on a printed-wiring board or across the surface of an optoisolator. Clearance is the shortest distance through air (straight line), such as from the pin-to-pin of a connector. The creepage and clearance distances vary depending on the working voltage, pollution degree and the material group (&#;proof tracking index&#;) that you are measuring across. The lower the proof tracking index of a material group, the shorter the required creepage and clearance. These are outlined in detail in EN-1 tables 2K, 2L, 2M, 2N. 


If you want to learn more, please visit our website class 1 insulation rubber foam.

 

 

 

Class I Equipment

This class of equipment utilises a protective earth (PE) ground connection to offer a means of protection in the event of insulation failure. The insulation from hazardous energy levels is only of basic levels, e.g. the primary winding of a AC-DC SMPS. The protective earth connection is there to protect the user if the insulation breaks down and the earth (chassis) becomes live. If a short to earth occurs, either the fuse will blow or, if fitted, the RCD will trip because the supplied current is no longer equal to the return current on the neutral.

It is wrong to assume that when using a Class I power supply the -DC return has the same potential as AC GND. Class I power supplies can still have floating outputs, as such the -DC return is not directly connected to AC earth, but it is separated by a capacitor which will not offer PE to your powered device. If your end piece of equipment requires PE then please ensure that the power supply is configured such that this is possible, either by using the negative DC return that is connected directly to PE or via another conductor.

FiDUS POWER datasheets always stipulate if the output is floating or AC earth bonded in the note section below the mechanical drawing of the unit. If the standard configuration is not suitable please contact sales for the other variant.

 

 

 

 

Class II Equipment

In Class II equipment protection is achieved with double or reinforced insulation rather than reliance on a PE and basic insulation, either because a reliable PE is not available or for other system-specific reasons. This insulation must withstand at least VAC ensuring the chances of exposed parts becoming live are significantly reduced. One knock-on design impact of this approach is EMC. Without an earth connection, EMC filtering is a much more difficult task and should be tackled early in the project as it can dictate the physical layout of the equipment&#;s&#; internal components. Some units are Class II but offer a Functional Ground (or FG) which is used for EMC purposes. Should there be no ground to connect to within the installation, we would recommend attaching any earthing points to a conductive plate underneath the power supply.

Class II insulation is not to be confused with the North American standard NEC (National Electrical Code) class 2 circuit. A class 2 circuit is the &#;limited power circuit&#; between the load and the isolated secondary circuit of a power source who&#;s rating is less than 100VA (or 5 times Vout if output voltage is lower than 20V).

Class III Equipment

This class uses a supply type known as a separated extra low voltage or SELV for short. It does not utilise an earth connection or require specific insulation other than functional. The unit must be supplied with no more than 60VDC or 42.4VAC for no longer than 200ms in normal operation. In single fault conditions the allowable limits are slightly higher at 71VAC and 120VDC for a maximum of 20ms. At these limits the circuit is considered to be safe and no harm will come as a result of direct contact.